Annals of Clinical Microbiology

Annals of Clinical Microbiology and AntimiCrObialS BioMed Centra

Abstract Background:

The objective of this study was to determine the contamination rate of the healthcare workers' (HCWs') mobile phones and hands in operating room and ICU. Microorganisms from HCWs' hands could be transferred to the surfaces of the mobile phones during their use.


200 HCWs were screened; samples from the hands of 200 participants and 200 mobile phones were cultured.


In total, 94.5% of phones demonstrated evidence of bacterial contamination with different types of bacteria. The gram negative strains were isolated from mobile phones of 31.3% and the ceftazidime resistant strains from the hands were 39.5%. S. aureus strains isolated from mobile phones of 52% and those strains isolated from hands of 37.7% were methicillin resistant. Distributions of the isolated microorganisms from mobile phones were similar to hands isolates. Some mobile phones were contaminated with nosocomial important pathogens. Conclusion: These results showed that HCWs' hands and their mobile phones were contaminated with various types of microorganisms. Mobile phones used by HCWs in daily practice may be a source of nosocomial infections in hospitals. Background Nosocomial infection is an important problem in all modern hospitals.

As early as 1861 Semmelweis [1] dem- onstrated that bacteria were transmitted to the patients by the contaminated hands of healthcare workers. Hospital operating rooms (OR) and intensive care units (ICU) are the workplaces that need the highest hygiene standards, also the same requirements for the personnel working there and the equipment used by them. Some epidemio- logical studies have implicated environmental surfaces in the transmission of bacteria [2-4]. Mobile phones are widely used as nonmedical portable electronic devices and it is in close contact with the body. It is used for com- munication by health care workers in every location including OR and ICU. Studies do not include direct com- parisons of transmission rates of bacteria from surfaces to Page 1 of 4 (page number not for citation purposes) Annals of Clinical Microbiology and Antimicrobials 2009, 8:7 http://www.ann-clinmicrob.eom/content/8/1/7 hands.

The risk of infection involved in using mobile phones in the OR and ICU has not yet been determined as there no cleaning guidelines available that meet hospital standards. However, the mobile phones are used rou- tinely all day long but not cleaned properly, as health care workers' (HCW) may do not wash their hands as often as they should. The aim of the present study was to evaluate the role of mobile phones in relation to transmission of bacteria from the mobile phone to the healthcare workers' hands.

Methods The study was conducted in the eight beds of the mixed tertiary intensive care unit and 14 operating rooms. A total 200 staff - 15 senior, 79 assistant doctors, 38 nurses and 68 healthcare staff - were screened; cultures were subse- quently obtained from the dominant hand of participants and their mobile phones at the same time. Gender, profes- sion and duration of their profession, ring use, dominant hands of HCWs, routine cleaning of the mobile phones was recorded. A sterile swab moistened with sterile saline was rotated over the surface of both sides of mobile phones; second swab was rubbed over the entire ventral surface of the dominant hand (including ventral surfaces of the thumb and the fingers) of HCW's.

The sampling of the dominant hand and mobile phone swabs (twice for hands and twice for mobile phones) were immediately streaked onto two plates that consist of blood agar supple- mented with 5% defibrinated sheep blood and eosin methylene blue agar. Plates were incubated aerobically at 37C for 48 h. Isolated microorganisms were identified using gram stain, colony counts, morphology, catalase and oxidase reaction and all isolates were allocated to the appropriate genera. For identification of gram negative bacteria VITEK 2 (bioMerieux, France) system was used. A slide coagulase test differentiated staphylococcal isolates into Staphylococcus aureus and coagulase-negative sta- phylococci (CoNS). Oxacillin sensitivity of the Staphylo- cocci and ceftazidime sensitivity of the gram negative isolates were investigated by disk diffusion method according to Clinical Laboratory Standards (CLSI) criteria [5].

The protocol was approved by the ethical committee for human experimentation of Ondokuz Mayis University Faculty of Medicine and informed consent was obtained from the participants. Statistical analysis Categorical variables were assessed by Chi square analysis. Non-categorical findings were assessed by the student t test or Man-Whitney U test. P values < 0.05 were consid- ered significant. SPSS for Windows 13.0 software (SPSS Inc., Chicago, USA) was used for these analyses.

Results The rate of bacterial contamination of mobile phones is 94.5%. The isolated microorganisms from mobile phones and hands were similar (Table 1). Some of them are known to cause nosocomial infections. Hand contamina- tion rates of HCWs and their personal mobile phones are shown in Table 2. It was found that 49.0% of phones grew one bacterial species, 34.0% two different species, 11.5% three or more different species and no bacterial growth were identified in 5.5% of phones. Those S. aureus strains isolated from mobile phones of 52.0% and those strains isolated from hands of 37.7% were methicillin resistant. The gram negative strains were isolated from mobile phones of 31.3% and the ceftazi- dime resistant strains from the hands were 39.5%. At the study period our nosocomial isolates at ICU were: 33.3% staphylococci, 21.4% non-fermentative gram negatives, 21.4% coliforms, 7.1% enterococci, 11.9% yeasts. The rate of routine cleaning of HCW's mobile phones was 10. 5%, which means 89.5% of the participants never cleaned their mobile phones. Although the assistant doc- tors' phones have higher colony count there was no signif- icant difference in the rates of specific types of bacterial growth and colony counts isolated on all groups' mobile phones (Table 2). 25.5% of the entire study population had one or more rings. The mean colony count was higher in ring using staff's phones but there was no significant difference between rate of contamination and colony count (Table 2) (p > 0.05). Discussion In this study, the use of mobile phones by HCWs working in OR and ICU not only demonstrated a high contamina- tion rate with bacteria but also more importantly contam- ination with nosocomial pathogens. The possibility transmissions of nosocomial pathogens by electronic devices such as personal digital assistants, handheld com- puters, and bedside applications were previously reported and some of them were epidemiologically important drug-resistant pathogens [6,7]. Isaacs et al. [6] showed that the main growth was of coagulase-negative staphylo- cocci from 25 keyboards. Two keyboards grew S. aureus, both of which samples were susceptible to methicillin/flu- cloxacillin. Neely et al. [8] also identified nosocomial A. baumannii infection on keyboards as a reservoir in burn units and ICUs. Butz et al. [9] stated that immobile phones might carry pathogens as well; stationary phones in a daycare facility were contaminated with rotavirus Rusin et al. [10] documented that hand-to-mouth transfer of microbes after handling contaminated fomites during casual activities. Singh et al. [11] reported that over 47% of immobile phones were contaminated with pathogenic microbes. These results suggested that close contact objects that were contaminated could serve as reservoirs of bacteria where could be easily transmitted from the mobile phone to the HCWs' hands.

During every phone call the mobile phones come into close contact with strongly contaminated human body areas with hands to hands and hands to other areas (mouth, nose, ears). Herein mobile phones are particularly problematic when compared to immobile devices and it may facilitate transmission of bacterial iso- lates from patient to patient in wards or hospitals. Some authors [12,13] showed that HCWs' mobile phones were contaminated with nosocomial pathogens.

The result of our study demonstrated cross transmission of bacteria between HCWs' dominant hands and one third of mobile phones. Gram negative bacteria are very impor- tant nosocomial pathogens and HCWs' mobile phones were carried ceftazidime resistant Gram negative isolates and half of S. aureus isolates were resistant to methicillin. However, this study was carried on a limited scale as no molecular tests were conducted for showing clonal rela- tion.

Our study demonstrated that the isolated microorganisms from hands and phones were similar. It is clear that it is not possible to estimate the level of bacterial contamina- tion with one sampling technique. Borer at al. [12] observed that there were contaminations of hands and mobile phones only in 10% of their staff who were sam- pled for once. The present study was nevertheless similarly planned; in this study contamination rate of the mobile phones was 94.5% for one sampling. Since no warning has been given for cleaning mobile phones to meet hospi- tal standards, the same rates and composition of contam- ination of mobile phones could be risky when carried outside the hospital environment. Limitation or crack- down of these items would be unpractical strategies for preventing nosocomial transmission, because mobile phones are used by the personnel both in private commu- nication and emergency situations in ICU so; cross-trans- missions between hands to mobile phones were assessed. Although it seems impossible, in the light of all these find- ings, we should be aware of limiting the mobile phone usage as it has high risk for spreading infections. According to these results it is obvious that, the training of healthcare personnel about strict infection control proce- dure, hand hygiene, environmental disinfection, and eventually, optimum disinfection methods are of great importance. Otherwise, the potential benefit of using mobile phones by the personnel for private communica- tion or emergency situations in ICU or OR would change into this means of communication detrimental to hospi- tal hygiene. Therefore, near the hand hygiene, cleaning of these devices should be kept in mind. Prevention of con- tamination risk of nosocomial pathogens and infections stands out as problem that must be weighed in mind. Developing active preventive strategies like routine decon- tamination of mobile phones with alcohol containing disinfectant materials might reduce cross-infection. Another way of reducing bacterial contaminations on mobile phones might be the use of antimicrobial additive materials. We could easily avoid spreading bacterial infec- tions just by using regular cleansing agents and rearrang- ing our environment. In the future mobile phones could be produced by using protective material against the bac- terial contamination. Competing interests The authors declare that they have no competing interests.

Authors' contributions FU carried out the design of the study, participated in the sequence alignment and drafted the manuscript. SE par- ticipated in the design of the study and performed the sta- tistical analysis. AD participated in the sequence alignment and helped to draft the manuscript. MG and KY carried out the microbiological procedures. HL conceived of the study, and participated in its design and coordina- tion. All authors have read and approved the final manu- script.


1. Semmelweis IP:

Die Aetilogie, der Begriff und die Prophylaxis des Kindbettfiebers.

Budapest: C.A. Hartleben's Verlags-Expedi- tion; 1861. 2. Ekanem EE, Dupont HL, Pickering LK, Selwyn BJ, Hawkins

CM: Transmission dynamics of enteric bacteria in day-care cent- ers. American Journal of Epidemiology 1983, 1 18:562-572. 3. Manning ML, Archibald LK, Bell LM, Banerjee SN, Jarvis WR: Serra- tia marcescens transmission in a pediatric intensive care unit: a multifactorial occurrence. Am J Infect Control 2001, 29:115-119. 4. Bures S, Fishbain JT, Uyehara CF, Parker JM, Berg BW: Computer keyboards and faucet handles as reservoirs of nosocomial pathogens in the intensive care unit.

Am J Infect Control 2000, 28:465-471. 5. Wikler Matthew A: Performance Standards for Antimicrobial Disk Susceptibility Tests; Approved Standard. Volume M02- A9. Ninth edition. Clinical and Laboratory Standards Institute (CLSI); 2006:52. 6. Isaacs D, Daley A, Dalton

D: Swabbing computers in search of nosocomial bacteria. Ped Infect Dis J 1998, 17:533. 7. Bellamy K, Laban KL, Barreto KE, Talbot DC: Detection of viruses and body fluids which may contain viruses in the domestic environment. Epidemiol Infect 1998, 121:673-680. 8. Neely AN, Maley MP, Warden GD: Computer keyboards as res- ervoirs for Acinetobacter baumannii in a burn hospital. Clin Infect Dis 1999, 29:1358-1360. 9. Butz AM, Fosarelli P, Dick J, Cusack T, Yolken R: Prevalence of rotavirus on high risk fomites in day-care facilities. Pediatrics 1993, 92:202-205. 10. Rusin P, Maxwell S, Gerba

C: Comparative surface-to-hand and fingertip-to-mouth transfer efficiency of gram-positive bac- teria, gram-negative bacteria, and phage. J Appl Microbiol 2002, 93:585-592. 1 1. Singh V, Aggarwal V, Bansal S, Garg SP, Chowdhary N: Telephone mouthpiece as a possible source of hospital infection. J Assoc Physicians India 1998, 46:372-373. 12. Borer A, Gilad J, Smolyakov R, et al.: Cell phones and Acineto- bacter transmission. Emerg Infect Dis 2005, 11:1160-1161. 13. Brady RR, Wasson A, Stirling I, McAllister C, Damani NN: Is your phone bugged?

The incidence of bacteria known to cause nosocomial infection on healthcare workers' mobile phones. J Hosp Infect 2006, 62:123-125. Publish with BioMed Central and every scientist can read your work free of charge "BioMed Central will be the most significant development for disseminating the results of biomedical research in our lifetime." Sir Paul Nurse, Cancer Research UK Your research papers will be:

available free of charge to the entire biomedical community

peer reviewed and published immediately upon acceptance

cited in PubMed and archived on PubMed Central


you keep the copyright Submit your manuscript here: f J BioMedcentral

^ Page 3 of 4 (page number not for citation purposes) http://www.ann-clinmicrob.eom/content/8/1/7 Annals of Clinical Microbiology and Antimicrobials 2009,

8:7 Page 5 of 4 (page number not for citation purposes) Annals of Clinical Microbiology and Antimicrobials 2009,

8:7 Page 6 of 4 (page number not for citation purposes)

Please be aware that the free essay that you were just reading was not written by us. This essay, and all of the others available to view on the website, were provided to us by students in exchange for services that we offer. This relationship helps our students to get an even better deal while also contributing to the biggest free essay resource in the UK!